Instruction No. 111

INSTRUCTION CONCERNING INVESTIGATION
AND REPORT OF THE PRESENT CONDITION
OF ELECTRICAL POWER PLANTS
AND PRIME MOVERS

November 5, 1942

Hon. JORGE B. VARGAS
Chairman of the Executive Commission
Manila

You are hereby instructed to make an investigation regarding the electrical generators and prime movers of all electrical enterprises and private installations in the Philippines. The report shall be made out in accordance with the following detailed items and submitted to this Administration not later than the end of the current year.

However, for power installations in use by enterprises or factories under Military control, it will be sufficient to mention only the location and purpose or the name of the concern.

(1) Power plants with internal combustion engine driven generators:

1. Location

2. Name of owner

3. Purpose (indicate if for electrical enterprise or for private consumption as well as main use and products)

4. Territory served

5. Internal combustion engine (s):

a. Type
b. Name of manufacturer
c. Date of manufacture
d. R. P. M.
e. Rated capacity in Horse Power
f. Number of units

6. Generator (s):

a. State whether belted or directly connected to Prime Mover
b. Name of manufacturer
c. Date of manufacture
d. Type
e. R. P. M.
f. Voltage …………. Current ………… Frequency
g. Rated capacity in KVA
h. Number of units

7. State whether or not in good operating condition

8. If not in good operating condition, state the extent of damage:

a. Internal combustion engine (s)
b. Generator(s)
c. Auxiliaries

9. Fuel:

a. Kind
b. Quantity consumed per day
c. Amount of present stock
d. Availability in the future
e. Remarks on suitability and efficiency of fuel

10. Load:

a. Daily Kilowatt Hours now produced
b. Present Night Peak Load in KW
c. Present Day Peak Load in KW
d. Probable daily Kilowatt Hours to be produced at the end of 1942
e. Probable Night Peak Load in KW at die end of 1942
f. Probable Day Peak Load in KW at the end of 1942

(2) Power plants with steam-driven generators:

1. Location

2. Name of owner

3. Purpose (indicate if for electrical enterprise or for private consumption as well as main u=e and products)

4. Territory served

5. Steam engine(s) or steam turbine(s):

a. Kind
b. Name of manufacturer
c. Date of manufacture
d. R. P. M.
e. Type
f. Rated capacity In Horse Power
g. Number of units

6. Boiler(s):

a. Name of Manufacturer
b. Date of manufacture
c. Type
d. Rated capacity in Horse Power
e. Number of units

7. Generator (s) :

a. State whether belted or directly connected to Prime Mover
b. Name of manufacturer
c. Date of manufacture
d. Type
e. R. P. M.
f. Voltage ……….. Current …… Frequency
g. Bated capacity in KVA

8. State whether or not in good operating condition

9. If not in good operating condition, state the extent of damage:

a. Steam engine
b. Generator
c. Boilers
d. Accessories

10. Fuel:

a. Kind
b. Quantity consumed per day
c. Amount of present stock
d. Availability in the future
e. Remarks on suitability and efficiency of fuel

11. Load:

a. Daily Kilowat Hours now produced
b. Present Night Peak Load In KW
c. Present Day Peak Load in KW
d. Probable Daily Kilowatt Hours to be produced at the end of 1942
e. Probable Night Peak Load in KW at the end of 1942
f. Probable Day Peak Load in KW at the end of 1942

(3) Power plants with water-driven generators:

1. Location

2. Name of owner

3. Purpose (indicate if for electrical enterprise or for private consumption as well as main use and products)

4. Territory served

5. Hydro turbine(s):

a. Kind
b. Name of manufacturer
c. Date of manufacture
d. R. P. M.
 e. Type
f. Rated capacity in Horse Power
g. Number of units
h. Head

6. Generator (s) :

a. State whether belted or directly connected to Prime Mover
b. Name of manufacturer
c. Date of manufacture
d. Type
e. R. P. M.
f. Voltage…………… Current ……………. Frequency
g. Rated capacity in KVA
h. Number of units

7. State whether or not the units are in good operating condition

8. If not in good operating condition, state the extent of damage:

a. Hydro turbine(s)
b. Generator(s)
c. Auxiliares

8. Load:

a. Kilowatt Hours now produced per day
b. Present Night Peak Load in KW
c. Present Day Peak Load in KW
d. Probable daily Kilowatt Hours to be produced at the end of 1942
e. Probable Night Peak Load in KW at the end of 1942
f. Probable Day Peak Load in KW at the end of 1942

(4) Internal combustion engine (s) as direct source(s) of power:

1. Location

2. Name of owner

3. Purpose

4. Internal Combustion Engine(s):

a. Kind
b. Name of manufacturer
c. Date of manufacture
d. R. P. M.
e. Type
f. Rated capacity in Horse Power
g. Number of units

5. State whether or not in good operating condition

6. If not in good operating condition, state the extent of damage:

a. Internal Combustion Engine(s)
b. Auxiliares

7. Fuel:

a. Kind
b. Quantity consumed per day
c. Amount of present stock
d. Availability in the future
e. Remarks on suitability and efficiency of fuel

DIRECTOR GENERAL